{"id":68179,"date":"2025-04-28T16:48:31","date_gmt":"2025-04-28T13:48:31","guid":{"rendered":"https:\/\/unox.com.tr\/steam-meter-vortex-flow-meter\/"},"modified":"2025-04-28T16:48:31","modified_gmt":"2025-04-28T13:48:31","slug":"steam-meter-vortex-flow-meter","status":"publish","type":"product","link":"https:\/\/unox.com.tr\/en\/steam-meter-vortex-flow-meter\/","title":{"rendered":"Steam Flow Meter (Vortex Flowmeter)"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Sayfa \u0130\u00e7eri\u011fi<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/unox.com.tr\/en\/steam-meter-vortex-flow-meter\/#What_Is_a_Steam_Flow_Meter_Vortex_Flowmeter\" >What Is a Steam Flow Meter (Vortex Flowmeter)?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/unox.com.tr\/en\/steam-meter-vortex-flow-meter\/#How_Does_a_Steam_Flow_Meter_Vortex_Flowmeter_Work\" >How Does a Steam Flow Meter (Vortex Flowmeter) Work?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/unox.com.tr\/en\/steam-meter-vortex-flow-meter\/#Key_Features_of_Steam_Meters\" >Key Features of Steam Meters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/unox.com.tr\/en\/steam-meter-vortex-flow-meter\/#Why_Are_Vortex_Flow_Meters_Preferred_in_Steam_Applications\" >Why Are Vortex Flow Meters Preferred in Steam Applications?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/unox.com.tr\/en\/steam-meter-vortex-flow-meter\/#Key_Considerations_for_Steam_Meters\" >Key Considerations for Steam Meters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/unox.com.tr\/en\/steam-meter-vortex-flow-meter\/#The_Right_Solution_for_Energy_Monitoring_%E2%80%93_Vortex_Steam_Flow_Meter\" >The Right Solution for Energy Monitoring \u2013 Vortex Steam Flow Meter<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"What_Is_a_Steam_Flow_Meter_Vortex_Flowmeter\"><\/span>What Is a Steam Flow Meter (Vortex Flowmeter)?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"276\" data-end=\"756\">What Is a Steam Flow Meter (Vortex Flowmeter)?<br \/>In industrial facilities, energy efficiency and system optimization have become more important than ever. In this context, questions such as \u201cWhat is a steam flow meter?\u201d or \u201cHow does a vortex flowmeter work?\u201d are frequently raised. A steam flow meter is used to accurately measure the flow rate of steam passing through a system, particularly by means of flowmeters operating on the vortex principle. These devices play a critical role in energy monitoring, cost analysis, and overall system control.    <\/p>\n<p data-start=\"758\" data-end=\"870\">For a detailed product range and technical support, you can visit the official Unox website: <a class=\"\" href=\"https:\/\/unox.com.tr\/\" target=\"_new\" rel=\"noopener\" data-start=\"850\" data-end=\"870\">unox.com.tr<\/a><\/p>\n<h2 data-start=\"872\" data-end=\"921\"><span class=\"ez-toc-section\" id=\"How_Does_a_Steam_Flow_Meter_Vortex_Flowmeter_Work\"><\/span>How Does a Steam Flow Meter (Vortex Flowmeter) Work?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"923\" data-end=\"1277\">The basic operating principle of vortex flowmeters is based on counting the vortices generated by a specially shaped body (vortex shedder) placed in the flow path. When steam strikes this body, vortices are formed alternately on either side downstream. The frequency of these vortices (number per second) is directly proportional to the steam flow velocity and, consequently, to the volumetric flow rate.  <\/p>\n<p data-start=\"1279\" data-end=\"1527\">Sensors detect these vortex frequencies, and the electronic system uses this data to calculate the steam flow rate in kg\/h or t\/h. In summary:<br \/>The faster the flow, the more vortices are generated.<br \/>\nThe number of measured vortices directly indicates the steam flow rate. <\/p>\n<p data-start=\"1529\" data-end=\"1603\">For detailed information and technical documentation: <a class=\"\" href=\"https:\/\/www.unoxonline.com.tr\/\" target=\"_new\" rel=\"noopener nofollow\" data-start=\"1573\" data-end=\"1603\">unoxonline<\/a><\/p>\n<h2 data-start=\"1605\" data-end=\"1648\"><span class=\"ez-toc-section\" id=\"Key_Features_of_Steam_Meters\"><\/span>Key Features of Steam Meters<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"1650\" data-end=\"1727\">Steam vortex flow meters offer advantages beyond conventional flow meters:<\/p>\n<ul data-start=\"1729\" data-end=\"2116\">\n<li data-start=\"1729\" data-end=\"1780\">\n<p data-start=\"1731\" data-end=\"1780\">They have no moving parts \u2013 low maintenance requirement<\/p>\n<\/li>\n<li data-start=\"1781\" data-end=\"1864\">\n<p data-start=\"1783\" data-end=\"1864\">They are compatible with different types of steam, such as dry, wet, or superheated steam.<\/p>\n<\/li>\n<li data-start=\"1865\" data-end=\"1914\">\n<p data-start=\"1867\" data-end=\"1914\">They are resistant to a wide range of temperatures and pressures.<\/p>\n<\/li>\n<li data-start=\"1915\" data-end=\"2020\">\n<p data-start=\"1917\" data-end=\"2020\">Multivariable models are available that can optionally operate integrated with temperature and pressure sensors.<\/p>\n<\/li>\n<li data-start=\"2021\" data-end=\"2116\">\n<p data-start=\"2023\" data-end=\"2116\">They can perform mass flow measurement, providing high accuracy in energy management and cost analysis.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2118\" data-end=\"2329\">Thanks to these features, steam meters are preferred for energy management, production control, and billing systems. For relevant technical details, you may contact Unox: <a class=\"\" href=\"https:\/\/unox.com.tr\/iletisim\/\" target=\"_new\" rel=\"noopener\" data-start=\"2300\" data-end=\"2329\">unox<\/a> <\/p>\n<h2 data-start=\"2331\" data-end=\"2386\"><span class=\"ez-toc-section\" id=\"Why_Are_Vortex_Flow_Meters_Preferred_in_Steam_Applications\"><\/span>Why Are Vortex Flow Meters Preferred in Steam Applications?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"2388\" data-end=\"2567\">High-temperature and high-pressure fluids such as steam require specialized instruments. Vortex flow meters are durable devices specifically designed for these environments. In addition:  <\/p>\n<ul data-start=\"2569\" data-end=\"2738\">\n<li data-start=\"2569\" data-end=\"2602\">\n<p data-start=\"2571\" data-end=\"2602\">They provide high measurement accuracy.<\/p>\n<\/li>\n<li data-start=\"2603\" data-end=\"2648\">\n<p data-start=\"2605\" data-end=\"2648\">They easily adapt to different process conditions.<\/p>\n<\/li>\n<li data-start=\"2649\" data-end=\"2703\">\n<p data-start=\"2651\" data-end=\"2703\">They operate reliably and have a long service life in industrial environments.<\/p>\n<\/li>\n<li data-start=\"2704\" data-end=\"2738\">\n<p data-start=\"2706\" data-end=\"2738\">They minimize energy losses.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2740\" data-end=\"2922\">In addition, the vortex flow meters offered by Unox can be easily integrated into automation systems. For the product catalog and technical support services, please visit: <a class=\"\" href=\"https:\/\/www.unoxonline.com.tr\/\" target=\"_new\" rel=\"noopener nofollow\" data-start=\"2892\" data-end=\"2922\">unoxonline<\/a> <\/p>\n<h2 data-start=\"2924\" data-end=\"2972\"><span class=\"ez-toc-section\" id=\"Key_Considerations_for_Steam_Meters\"><\/span>Key Considerations for Steam Meters<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"2974\" data-end=\"3090\">To obtain accurate and reliable data from a steam meter, certain points should be considered during installation and operation:<\/p>\n<p data-start=\"3092\" data-end=\"3287\">1. Correct Pipe Diameter and Straight Pipe Length:<br \/>\nThere should be sufficient straight pipe lengths upstream and downstream of vortex meters (typically at least 10D at the inlet and 5D at the outlet). This significantly improves measurement accuracy. <\/p>\n<p data-start=\"3289\" data-end=\"3490\">2. Condensate Management:<br \/>\nCondensate formed in steam lines can cause inaccurate measurements. Therefore, suitable condensate drainage devices (such as steam traps) must be installed on the line. <\/p>\n<p data-start=\"3492\" data-end=\"3765\">3. Temperature and Pressure Compensation:<br \/>\nSome advanced vortex flow meters measure temperature and pressure as well, compensating for density variations. This allows for more accurate mass flow measurement. For detailed information on such advanced devices: <a class=\"\" href=\"https:\/\/unox.com.tr\/\" target=\"_new\" rel=\"noopener\" data-start=\"3745\" data-end=\"3765\">unox<\/a>  <\/p>\n<p data-start=\"3767\" data-end=\"3938\">If you would like to receive professional support regarding installation, commissioning, or product selection, you may contact the Unox expert team: <a class=\"\" href=\"https:\/\/www.unoxonline.com.tr\/iletisim\/Unox provides high-quality and reliable actuator systems for industrial automation solutions. With a comprehensive product range, Unox offers solutions designed to meet a wide variety of industrial requirements. To find the most suitable actuator solutions for your application, please visit the Unox Contact page for professional support.3. Unox and Unox Online: Supplying Industrial Automation Valves\" target=\"_new\" rel=\"noopener nofollow\" data-start=\"3899\" data-end=\"3938\">unoxonline<\/a><\/p>\n<h2 data-start=\"3940\" data-end=\"4000\"><span class=\"ez-toc-section\" id=\"The_Right_Solution_for_Energy_Monitoring_%E2%80%93_Vortex_Steam_Flow_Meter\"><\/span>The Right Solution for Energy Monitoring \u2013 Vortex Steam Flow Meter<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p data-start=\"4002\" data-end=\"4356\">Accurate measurement in steam systems is critical not only for energy savings but also for process safety. Vortex flow meter technology is one of the most effective ways to measure steam flow reliably and economically, with low maintenance costs. For maximum efficiency and control in your industrial processes, you can choose vortex steam flow meters.  <\/p>\n<p data-start=\"4358\" data-end=\"4553\">With Unox\u2019s wide product portfolio and extensive field experience, you can easily find the most suitable solution for your system. For detailed information and quotation requests, you may use the links below: <\/p>\n<ul data-start=\"4555\" data-end=\"4718\">\n<li data-start=\"4555\" data-end=\"4623\">\n<p data-start=\"4557\" data-end=\"4623\">Main website:<a class=\"\" href=\"https:\/\/unox.com.tr\/\" target=\"_new\" rel=\"noopener\" data-start=\"4567\" data-end=\"4587\"> unox<\/a> and <a class=\"\" href=\"https:\/\/www.unoxonline.com.tr\/\" target=\"_new\" rel=\"noopener nofollow\" data-start=\"4591\" data-end=\"4621\">unoxonline<\/a><\/p>\n<\/li>\n<li data-start=\"4624\" data-end=\"4718\">\n<p data-start=\"4626\" data-end=\"4718\">Contact pages: <a class=\"\" href=\"https:\/\/unox.com.tr\/iletisim\/\" target=\"_new\" rel=\"noopener\" data-start=\"4646\" data-end=\"4675\">unox contact<\/a> and <a class=\"\" href=\"https:\/\/www.unoxonline.com.tr\/iletisim\/Unox provides high-quality and reliable actuator systems for industrial automation solutions. With a comprehensive product range, Unox offers solutions designed to meet a wide variety of industrial requirements. To find the most suitable actuator solutions for your application, please visit the Unox Contact page for professional support.3. Unox and Unox Online: Supplying Industrial Automation Valves\" target=\"_new\" rel=\"noopener nofollow\" data-start=\"4679\" data-end=\"4718\">unoxonline contact<\/a><\/p>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p><a href=\"https:\/\/unox.com.tr\/wp-content\/uploads\/2025\/04\/Vortex-Flowmeter.pdf\" target=\"_blank\" rel=\"noopener\"><button style=\"background-color: #11224b; color: #ffffff; padding: 10px 15px; font-family: montserrat; font-weight: bold; font-size: 19px; border-radius: 10px;\"><img decoding=\"async\" style=\"width: 25px; height: 25px;\" src=\"https:\/\/unox.com.tr\/wp-content\/uploads\/2023\/02\/pdf-1.png\">PRODUCT CATALOGUE<\/button><\/a><\/p>\n<p><button style=\"background-color: #11224b; margin-top: 5px; color: white; padding: 0px 15px; width: 150px; height: 55px; border-radius: 10px; border: none; cursor: default;\"><br \/>\n<img decoding=\"async\" style=\"width: 120px; height: 30px;\" src=\"https:\/\/unox.com.tr\/wp-content\/uploads\/2023\/02\/4-1.svg\"><\/button><\/p>\n","protected":false},"featured_media":63913,"comment_status":"open","ping_status":"closed","template":"","meta":{"_joinchat":[]},"product_brand":[],"product_cat":[1763,1406],"product_tag":[],"class_list":{"0":"post-68179","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-flow-meter","7":"product_cat-level-and-flow","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/unox.com.tr\/en\/wp-json\/wp\/v2\/product\/68179","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unox.com.tr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/unox.com.tr\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/unox.com.tr\/en\/wp-json\/wp\/v2\/comments?post=68179"}],"version-history":[{"count":0,"href":"https:\/\/unox.com.tr\/en\/wp-json\/wp\/v2\/product\/68179\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unox.com.tr\/en\/wp-json\/wp\/v2\/media\/63913"}],"wp:attachment":[{"href":"https:\/\/unox.com.tr\/en\/wp-json\/wp\/v2\/media?parent=68179"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/unox.com.tr\/en\/wp-json\/wp\/v2\/product_brand?post=68179"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/unox.com.tr\/en\/wp-json\/wp\/v2\/product_cat?post=68179"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/unox.com.tr\/en\/wp-json\/wp\/v2\/product_tag?post=68179"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}