Pneumatic Actuated Threaded Stainless Steel Ball Valve

45 People watching this product now!
Description

The pneumatic actuated threaded stainless steel ball valve gives fast on-off control with compressed air in water, steam and corrosive media lines. With its stainless steel body and UDA (double acting) or USA (single acting) series pneumatic actuator it suits frequently cycling automation lines.

Contents

Valve and Actuator

Valve typeBall valve
ConnectionThreaded
Body materialStainless steel
ActuatorUDA (double acting) or USA (single acting) series pneumatic actuator
ControlOn-off or proportional

Double Acting (UDA) Actuator Torque Values (Nm)

Model2 bar3 bar4 bar5 bar5.5 bar6 bar7 bar8 bar
U404.06.08.010.011.012.014.016.0
U528.512.717.021.223.425.529.734.0
U6315.022.030.037.541.144.952.459.9
U7524.737.149.561.968.074.286.699.0
U8332.548.765.081.289.397.4113.7130.0
U9246.569.893.0116.3128.0140.0162.9186.0
U10569.3104.0138.5173.2190.5207.8242.5277.0
U125122.7184.0245.5306.8337.5368.0429.5490.8
U140184.7277.0369.5461.8508.0554.0646.5739.0
U160281.54225637047748449851126
U19045368090711341247136115871814
U210623935124615581714187021822493
U2409771465195424432687293134203908
U27013742061274834353778412248095496

Torque values depend on the air pressure; the actuator is selected so that it delivers the torque the valve needs at the lowest air pressure available on site.

Common Specifications

ModelsU40 – U270
Rotation angle90° (120° on request)
Air connectionG 1/4″ (U240: G 1/4″ – G 1/2″)
Housing materialExtruded aluminium body, aluminium pistons and end caps
Shaft1040 transmission steel
SealsNBR, Viton
StandardsISO 5211, DIN 3337, VDI/VDE 3845 (NAMUR)
Control typeOn-off or proportional

The torque of a single acting actuator depends on the number of springs and the air pressure; the torque and spring arrangement tables are in the product catalog.

How Does It Work?

When compressed air is supplied to the actuator, the pistons move and the rack-and-pinion mechanism converts this movement into a 90° rotation of the shaft, opening or closing the valve. In the double acting type the valve is both opened and closed by air; in the single acting type the springs return the valve to its safe position on their own when the air is cut off.

Applications

  • Remote on-off control of water and process lines
  • Timed or signal-controlled lines in automation systems
  • Tank filling and draining lines

Selection

The right model is selected by considering the valve size, medium, operating pressure and temperature together with the air pressure available on site and the control method. Send us your application and our technical team will recommend the right model.

For other models see our pneumatic actuated valve category; if you only need an actuator, see the pneumatic actuators page; for types and the working principle, read our what is a pneumatic valve guide.